Honda Tsivik + Cars of the Honda Civic and Acura Integra brand + Maintenance instruction + Routine maintenance + Engine + Cooling system and heating + Power supply system and release + Engine electric equipment + Control systems of the engine - Gear shifting box + 5-staged manual box of gear shifting - 4-staged and stepless automatic transmissions (ат and cvt) General information Failure diagnostics of AT/CVT - the general information Check and adjustment of a cable of management of a butterfly valve in the kick-down mode (TV cable) - the Integra models Replacement and adjustment of a cable of gear shifting Adjustment and replacement of the sensor switch of position of the lever of the selector of transfers System of blocking - the general information, check of a state, replacement and adjustment of an electromagnet of management Check and replacement of electromagnetic valves of management of blocking Removal and installation of 4-staged and stepless automatic transmissions (AT and CVT) + Coupling and power shafts + Brake system + Suspension bracket and steering + Body + Onboard electric equipment
|
Check and replacement of electromagnetic valves of management of blocking
Check Electromagnetic valve of management of blocking
|
|
1. Disunite the electric socket of assembly of the electromagnetic valve of management of blocking (see an accompanying illustration). |
2. Measure resistance between each of socket plugs (from the valve) and weight. Compare results of measurements to requirements of Specifications. In case of need replace assembly of the valve. 3. Serially connect each of socket plugs to a positive pole of the battery, – distinctly heard click accompanying operation of each of valves has to sound. If the click is not heard, it is necessary to drive away the car on car repair shop for performing full-scale diagnostics of ESM and contours of electromagnetic valves. |
|
Electromagnetic valve of management of gear shifting blocking
|
|
1. Disunite the electric socket of the electromagnetic valve of management of gear shifting blocking (see an accompanying illustration). |
2. Measure resistance between each of socket plugs (from the valve) and weight. Compare results of measurements to requirements of Specifications. In case of need replace assembly of the valve. 3. Serially connect each of socket plugs to a positive pole of the battery, – distinctly heard click accompanying operation of each of valves has to sound. If the click is not heard, it is necessary to drive away the car on car repair shop for performing full-scale diagnostics of ESM and contours of electromagnetic valves. 4. Serially connect each of socket plugs to a positive pole of the battery, – distinctly heard click accompanying operation of each of valves has to sound. If the click is not heard, it is necessary to drive away the car on car repair shop for performing full-scale diagnostics of ESM and contours of electromagnetic valves. |
|
Replacement
|
It is not possible to make replacement of only one of electromagnetic valves in an individual order. All valvate assembly (the valve of management of blocking and the valve of management of gear shifting blocking) is subject to replacement.
|
|
|
1. Give fixing bolts and remove valvate assembly (see an accompanying illustration). |
2. Carefully wipe the interfaced surfaces and clean maslotok. 3. Replace sealing laying and establish new valvate assembly on the regular place. Tighten fixing bolts with the required effort. 4. Check the electric socket for existence of signs of pollution and oxidation, in case of need clean and again connect. 5. Check serviceability of functioning of electromagnetic valves of management (see above). |
|
|
|